I am working on a steam generator efficiency project.

Here is a sample data :

Amount of Feedwater - 12.33 m^3/hour = 12000 kg/hr (assuming density = 1000 kg/m^3) 

Amount of Steam generated - 14450 kg/hr

By the following efficiency formula, it is more than 100%

Efficiency = (Steam generated/Amount of feedwater coming in)*100

I have values from the past 3 months and the value consistently stays above 110 %. Can anybody please explain this? I have ruled out error in the measuring instruments.