In the attached file is dsc of my sample. I have numbered the peaks seen inthe graph. I am seeing three peaks endothermic other than melting. so can u u identify which one is glass transition peak
Hi,
Your graohs are quit confusing. But anyway i could say that fir graph. Better try with NETZACH German machines
1-62C
2- 33C
3- 75C
Lets verify with other researchers what they say.
Best
Can you share the orginal pdf drived from your analyze machine? This one is so unclear. If you share that maybe i can help.
the Tg does not show up as peak, but it is a step change. i.e. a change like the one next the numbers in your graph.
all the best
you can try take the first derivative of your DSC curves, then Tg will appear as a peak.
thanks for your answers
out of the endothermic peaks which is the glass transition temperature
02 March 2019 7,054 9 View
What is the phenomenon behind the peak at 410K?Please help me
06 July 2018 6,777 1 View
irn the figure given actual melting point is 423k but I am getting melting peak in this temperature aswell as a peak lower than this temperature..what phenomenon does the up peak below melting point
06 July 2018 8,832 1 View
I need a very narrow glass capillary for my research. How can I make a glass capillary with an inner diameter of around 200 to 500 nanometers?
08 August 2024 8,915 0 View
I am planning to collect human fecal samples for metatranscriptomic analysis using MGI. These samples are from indigenous people living in a region with high temperatures. I will have access to a...
06 August 2024 1,367 3 View
During low-temperature testing, new diffraction peaks that appear could be indicative of several phenomena. In one of our tests, we observed notable new peaks around 40° and 45° in a specific...
06 August 2024 726 3 View
I got comment on my FTIR data figure from a reviewer. The reviewer said "FTIR data in Figure should be repeated. there is no bassline." I made Y off set comparison graph of FTIR on OriginLab. Can...
03 August 2024 6,070 3 View
for eg. transition shock scale
01 August 2024 5,998 0 View
Do these peaks in the curve indicate primer dimer or non-specific products?
01 August 2024 7,466 0 View
A typical reforming section in a large-scale Haber-Bosch process (Figure 1) comprises two reactors. A mixture of methane (CH4) and steam (H2O) is fed into a primary reformer to produce syngas via...
01 August 2024 7,051 5 View
I have used Prussian blue nanoparticles as a redox couple. The PBNPs have been made using only one salt precursor. Also, during scan rate studies, a small oxidation peak can be consistently found...
31 July 2024 9,697 0 View
Hi everyone, I'd like to better separate two close peaks coming from a bioconversion sample, I'm currently using a C18 KromaPhase 4,6mm Ø.I. SCHARLAU, particle size (µm): 10, pore size (Å): 100,...
30 July 2024 435 3 View
The entropy measured of molecular graphs plays a crucial rule. The network structures in some cases are very lengthy calculations to handle. Some author avoid to construct table where as most...
30 July 2024 3,126 0 View