I need to measure the intensity, at each frequency, of microwave radiation having a specific bandwidth with a central peak at 183 GHz. What sensors can be used for this purpose?
You may look at
https://www.gentec-eo.com/terahertz-power-meter/detectors
https://en.wikipedia.org/wiki/Golay_cell
http://terasense.com/products/detectors/
A mmwave spectrum analyzer will do this
https://www.keysight.com/main/editorial.jspx?cc=US&lc=eng&ckey=2153303&nid=null&id=2153303
You can use SEM-600, Beijing Safety Test Technology Co., Ltd., China
In physics, the description of the properties of light generally refers to its wavelength (nm), while in the range of microwaves and radio waves we refer to the frequency of a signal (e.g. kHz or...
03 March 2021 1,682 3 View
Is There Any Feasible Method To Test The Efficiency Of Fluorescent Compounds Other Than UV Spectrometers ? Suggestions Would Be Appreciated !
02 March 2021 5,785 3 View
28 February 2021 5,433 3 View
I am simulating helix antenna in hfss, right now, giving excitation with 50 ohms port. When I see the results of Z parameter (real). It shows lower than 50 ohms. Do not understand, if it can be...
27 February 2021 4,218 7 View
I am trying to obtain the response and recovery times for my gas sensor device. It appears the the response/recovery times are primarily dependant on the flow rate of the gas I inject into the...
26 February 2021 1,511 3 View
Dear Research Gaters, Let me first add context to the question. I am looking to simulate the waste management system and resources of a city. The hardware devices I need to simulate include,...
21 February 2021 2,333 4 View
Could the "incoming solar radiation" values be negative? What is the difference between "global solar radiation" and "incoming solar radiation"? Which one might be measured negative values?
21 February 2021 7,726 9 View
Hello, I'm working on removal of methylene blue. 01. in the dark test very first reading is taken 15 minutes after adding adsorbent to the dye solution and that UV absorbance reading is very...
19 February 2021 472 5 View
My team is designing a dual channel microfluidic chip that runs air and water. I think we've decided on the NE1000 syringe pump for it's versatility and feedback control. We will be ordering the...
18 February 2021 9,928 2 View
Hello researchers! While studying the literature on refractive index sensors, most of the articles simulate their devices with a refractive index ranging from 1 to 1.1, with small steps in...
17 February 2021 1,578 4 View