The UV-Vis absorption coefficient of PANi nano fibers dispersed in water is very low. What are the possible reasons behind this low value?
Absorption in solution is dependent on concentration, so increasing the concentration will increase the absorption.
The peaks at~4.2 eV, 5eV and 6eV are already saturated, however, your HOMO-LUMO looks like it is at 2.3 eV or even lower.
This is may be due to the need to balance stress at grain boundaries, and satisfy constraints on the strain tensor (for example a tensile stress along one direction must be balanced by a...
07 August 2015 1,891 8 View
If we treat the problem mathematically, then 10/100 = 1/10 but if we want to make a decision related to life, what would we choose?
07 August 2015 8,726 1 View
The reported values of energy gap of CZTS thin films are in the range 1.4-1.5 eV, however, my spray pyrolysis deposited CZTS thin films have more than 2 eV energy gap. What are the possible...
05 June 2015 5,648 9 View
In Classical gas, why the most probable energy of molecule is not the energy of a molecule moving at the most probable speed?
03 April 2015 7,810 2 View
01 February 2015 1,201 14 View
K2SO4 crystal is transparent color. The Cu doped K2SO4 crystal has light blue color. What is the exact mechanism behind this phenomenon?
01 February 2015 2,989 2 View
The photon CAN transfer part of its energy to the electron and continue to exist. An example of this is Compton scattering, where a gamma ray transfers enough energy to the electron to ionize and...
11 December 2014 2,286 6 View
The thin film solar cell is either n-i-p or p-i-n
11 December 2014 8,065 4 View
And how can we measure each one of them?
11 December 2014 5,087 8 View
Is There Any Feasible Method To Test The Efficiency Of Fluorescent Compounds Other Than UV Spectrometers ? Suggestions Would Be Appreciated !
02 March 2021 5,785 3 View
I anwar by adsorption or reaction ..but it is either more method...
02 March 2021 4,811 2 View
Question to you and THEM, the New Journal, "Integrative Psychological and Behavioral Science" -- do you not know, and have you not seen, this done before? There appears to be a core problem for...
02 March 2021 3,024 2 View
I took measurements of different concentrations of 15 nm and 5 nm Au nano particle solutions. I'm trying to determine which concentration I measured gives the best reading overall. I also...
02 March 2021 7,626 1 View
Hello every body Does any one has any idea to help me choose a reasonable basis set for intermediate metal ions (i.e Fe2+, Mn2+, Cu2+ and exc.) interactions with guanine or other DNA organic...
01 March 2021 6,187 2 View
I try to check the uv-vis absorption of Indium nanoparticle. Now I am measuring in solution, can I measure it in the form of a film?
01 March 2021 930 3 View
I am doing my thesis on the nutrient deprivation on the macroalgae Rhizoclonium sp. I will be analysing the levels over a period of roughly 5 days by HPLC-UV and GC/MS. I will be using seawater as...
28 February 2021 6,477 1 View
Im doing PBMC isolation -> CD14+ enrichment using magnetic beads -> stimulation setup. My negative control is just cells in cRPMI but they seem to get activated over and over again.
28 February 2021 7,883 3 View
Is there any reason for decrease in fluorescence emission intensity of HSA,BSA when increase the concentration ?
28 February 2021 3,653 4 View
What could be the reason of moisture at the sides of Vial when I am preparing my polmyer+DMSO solution for membrane fabrication? What etiquettes I am possibly missing here?
28 February 2021 6,516 5 View