I am testing using CHI 660C model electrochemical work station then I am getting discharge capacity more than the charging capacity? How is that possible?
Dear sir/Madam, I am depositing battery electrode materials (Lithium chromium oxide) in thin film form. I want to study the NMR spectra of these samples and correlate their electrochemical...
06 July 2018 8,744 1 View
I am trying to deposit ceramic oxide thin films from Lithium cobalt oxide target having difference roughness. Thanks
09 October 2015 5,073 11 View
02 March 2015 1,473 5 View
I want to know what is happening at the surface at the atomic scale which facilitates a rise in intensity. Thank you.
03 April 2014 9,150 2 View
.
08 September 2013 6,654 3 View
Relation between C-rate and current used for discharging the cell.
07 August 2012 3,623 16 View
I need to deposit a thin film of Tin (Sn) with grain size less than 300 nm.
06 July 2012 805 9 View
Thanks in advance.
06 July 2012 1,579 17 View
How does the purity of Lithium Cobalt Oxide cathodes for Li ion batteries effect the rate capability and cycle life?
05 June 2012 7,244 6 View
I have several question regarding the MOR; hope anyone help me better understand. 1- in CV using (KOH+MEOH) what is the indication of absence of the redox peaks? shouldn't they exist as a sign...
28 February 2021 4,851 8 View
As a beginner in electrochemistry, I tried to obtain cyclic voltamograms of commercial anatase powder deposited on an ITO substrate or on Eteck. After several attempts, I noticed that my cyclic...
23 February 2021 3,175 3 View
I performed a Proton NMR of graphene powder prepared by electrochemical exfoliation technique. It shows some peaks. But I can't understand it.
21 February 2021 8,947 3 View
Can anyone recommend some any software/models available that can predict substance reactivities and the reaction yield under a specific set of reaction conditions process and proposing pathways to...
17 February 2021 2,383 3 View
I have several questions, What reference electrodes is commonly used for aqueous electrochemical systems? What reference electrodes is commonly used for electrochemical systems which used...
06 February 2021 6,389 5 View
While surface roughness is an obvious factor, this is not what is exactly asked. Rather, periodic variation of exchange current density (of an electrode) with solution chemistry (of electrolyte)...
30 January 2021 4,886 5 View
I am trying to measure resistance from I-V curve from a chemiresistor/ FET sensor with a keithly sourcemeter. The substrate is soaked/ wet with protein and phosphate buffer only. But the I-V line...
24 January 2021 8,009 3 View
For example: In an electrochemical cell utilising a platinum (Pt) anode, what is the difference and what kind of implications would be expected from using either Pt(100), Pt(110) or Pt(111)?
20 January 2021 309 5 View
For electrochemical sensors, the electroactive surface area (ESA) show higher value for the working material as compared to bare (reported in several papers). My bare electrode is FTO and working...
17 January 2021 7,220 3 View
First of all, thank you for your consideration about this question. I've been working on development of in-vitro diagnostic medical device as research engineer since 2013. Especially, my major is...
14 January 2021 3,885 4 View