Why Raman peaks are fitted with Lorenzian profile?
Already someone raised this question in researchgate and some researchers answered for it. Please find the link to get your answer
https://www.researchgate.net/post/Why_are_Raman_spectra_peak-fited_with_Lorentzian_peaks
Also have a look at another article about Raman line shape
https://arxiv.org/ftp/arxiv/papers/1804/1804.06083.pdf
Thanks Sorb...
During Rietveld refinement of powder Xray diffraction data, the intensity of the higher angle peaks does not match well, but the lower angle peaks matches well with the calculated intensity for...
03 April 2019 8,224 3 View
Generally with increasing pressure, the XRD peaks are get shifted towards higher theta values. But there is always the FWHM of the peaks gets increases with pressure. Is the non hydrostatic...
10 November 2017 9,009 12 View
The figure shows DSC cooling (blue) and 2nd heating (green) curves (step: 10 K/min) for a commercial sample supplied as Atactic Polypropylene (APP). The heating curve illustrates two major...
03 March 2021 5,857 3 View
Question to you and THEM, the New Journal, "Integrative Psychological and Behavioral Science" -- do you not know, and have you not seen, this done before? There appears to be a core problem for...
02 March 2021 3,024 2 View
Hello Everyone. Currently I am working to characterize macrophages in the myocardium after ischemia-reperfusion injury in rats. Due to the low total cell number isolated from rat hearts I can...
01 March 2021 3,867 3 View
Hello every body Does any one has any idea to help me choose a reasonable basis set for intermediate metal ions (i.e Fe2+, Mn2+, Cu2+ and exc.) interactions with guanine or other DNA organic...
01 March 2021 6,187 2 View
I'm looking at the aggregation of my protein sample using DLS. Unfortunately, my buffer (20mM HEPES) also results in a set of peaks. These are at approximately 1 and 1000 d.nm. The lowest peak...
01 March 2021 9,015 2 View
Im doing PBMC isolation -> CD14+ enrichment using magnetic beads -> stimulation setup. My negative control is just cells in cRPMI but they seem to get activated over and over again.
28 February 2021 7,883 3 View
Is there any reason for decrease in fluorescence emission intensity of HSA,BSA when increase the concentration ?
28 February 2021 3,653 4 View
What could be the reason of moisture at the sides of Vial when I am preparing my polmyer+DMSO solution for membrane fabrication? What etiquettes I am possibly missing here?
28 February 2021 6,516 5 View
The reasoning behind this question is to align the ratios of the proton potential in energy per charge to the speed of light in distance per time. As these two dimensions appear to be related,...
27 February 2021 947 7 View
i have recorded raman spectra of strontium oxide thin film. the spectra were recorded in the range 400 to 4000 cm-1. i have reference to peaks upto 1000cm-1. but i couldn't find literature for...
26 February 2021 2,499 1 View