I couldn't found specific heat of urea formaldehyde resin
help~
Dear Kim Tae Woo,The specific heat of urea formaldehyde resin (Urea Formaldehyde Thermosetting Alfa cellulose filled) is 0.586 Cal/gram
regards
Prem Baboo
Basically you can estimate it with a formula when knowing the solids content of the product:
Example: solids content 66%
c = -2,38 x 0,66 + 4,18 = 2,61 kJ /kg /K
When I conducted the degassing experiment using decompression under anaerobic condition(and I used ferrous based chelating agent), the oxidized ferric were observerd. So, could you tell me the...
03 March 2021 4,892 5 View
Hi, everyone. I'm a starter to write a paper by Latex. But I have some difficulty using it. I'm writing the paper with 2 columns. And, there is one figure that occupies the 2 both-sides. I want to...
26 February 2021 3,738 3 View
Hello, I am a master's student studying in Yonsei Univeristy, Korea. I am trying to estimate the state of satellite, using Neural Network. Below is a simple flow of my study. 1. Train (t0 ~ t1)...
23 February 2021 6,383 3 View
23 February 2021 9,253 1 View
Hello, I've got a plan to isolate mouse splenic Treg (WT and KO of target gene) and inject these CD45.2 Treg into tumor-bearing CD45.1 mice. My question is how many days do I need to wait to see...
11 February 2021 8,238 1 View
For instance, I get a spectrum and the software incorrectly assigns a Si peak as W. If I don't catch it on the software and only have the report (which lists both wt% and at%), is there a way to...
10 February 2021 7,665 4 View
Hello, I studied how much bound my test antibodies to the target antigen using FITC labeling to test antibodies. I tested 3 types of antibodies, the elisa binding affinity and cytotoxicity...
07 February 2021 8,335 2 View
I am trying to run a cell viability assay with LN229, but these cells are cultured in DMEM which contain phenol red. Is the MTS assay sensitive to the additional of phenol red in the media? If so,...
03 February 2021 9,478 2 View
I am currently setting up our lab's behavioral space to run the open field test in rats, and I am trying to figure out how to set up lighting to evenly illuminate the open field chamber (a 90 cm x...
26 January 2021 1,399 3 View
Hi guys, I'm looking for a water-soluble dye which is not surface inactive in order to observe (water in oil) emulsions; I don't prefer to use oil-soluble dyes. I've used rhodamin123,...
21 January 2021 8,496 2 View
Increased heat, drought and insect outbreaks, all associated to climate change, have increased wildfires. Decreasing water supplies, declined agricultural yields, health impacts in cities owing to...
01 March 2021 7,168 9 View
Should I mesh the solid domain ? or should I use wall thickness? or Shell conduction? for Heat Transfer between two fluids of a Heat Exchanger. what is recommended?
01 March 2021 9,785 3 View
I want to cool Natural Gas from 195 Kelvin to 138 Klevin in a heat exchanger by using liquid nitrogen as the coolant medium. When entering the heat exchanger, the liquid nitrogen will have a...
01 March 2021 6,450 5 View
I have been trying to simulate heat transfer problem in Comsol 5.5 for long time but it always throw an error stating: "Failed to find a solution. Maximum number of Newton iterations...
28 February 2021 8,626 3 View
Hi Guys. I'm a mechanical engineer and have a bit trouble, would be very glad if you could help me with my questions. I have a pressurized tank which contains Natural Gas at 200 Bar and 293...
26 February 2021 6,253 3 View
Hi I am very new to proteomics analysis. I have got raw files from core facility running thermofisher TMT 16plex 4 hours. I cannot find on maxquant the option TMT16Plex there is only up to 11...
25 February 2021 1,675 3 View
Hi all, I have been doing research on biotagged LDB1 proteins in Mel cells. I purify the proteins using M280 streptavidin beads. The yield is very low so I've been trying to optimize it by...
24 February 2021 5,749 3 View
I'm building a cfx model of thermoplastic pultrusion process on ansys and i have a doubt on how is the proper way to set this parameter in a porous medium
24 February 2021 1,915 1 View
I'm doing a cfx simulation of a multiphase flow in pultrusion and i set the Interfacial Area density in the heat exchange of a porous medium in this way IAD=Total fiber lateral surface of fiber...
23 February 2021 6,043 1 View
I have a fixed sample and would like to use the murexide reaction to test for uric acid composition. I no longer have fresh samples
22 February 2021 1,328 1 View