Gate valves and choke valves are mechanically different and each one of them have their own functionality and usage. Therefore, for the purpose of throttling, is it possible to regulate the flow using a gate valve instead of a choke valve?
I am working on a project for designing matrix acidizing process for an oil well, and I am willing to use STIMPRO for designing that process. However I didn't have the chance to work on such a...
09 October 2015 7,887 3 View
I am conducting a research project about sand production control in oil wells. And I am in need of good references to rely on while conducting my research. Any help would be appreciated.
02 March 2015 1,391 5 View
Excessive rotation of nodes in node set ErrNodeExcessRotation-Step1
17 August 2021 0 0 View
20 June 2021 0 0 View
What this unit identifies for the ion exchange capacity ca. 0.92 meq. g-1. I am a newcomer in the membrane area. I just started. I highly appreciate your help
08 May 2021 0 0 View
--> FOAM FATAL ERROR: Maximum number of iterations exceeded From function Foam::scalar Foam::species::thermo::T(Foam::scalar, Foam::scalar, Foam::scalar, Foam::scalar (Foam::species::thermo::*)(Foam::scalar, Foam::scalar) const, Foam::scalar (Foam::species::thermo::*)(Foam::scalar, Foam::scalar) const, Foam::scalar (Foam::species::thermo::*)(Foam::scalar) const) const [with Thermo = Foam::hConstThermo >; Type = Foam::sensibleEnthalpy; Foam::scalar = double; Foam::species::thermo = Foam::species::thermo >, Foam::sensibleEnthalpy>] in file /home/ubuntu/OpenFOAM/OpenFOAM-4.1/src/thermophysicalModels/specie/lnInclude/thermoI.H at line 66. FOAM aborting #0 Foam::error::printStack(Foam::Ostream&) at ??:? #1 Foam::error::abort() at ??:? #2 Foam::heRhoThermo >, Foam::sensibleEnthalpy> > > >::calculate() at ??:? #3 Foam::heRhoThermo >, Foam::sensibleEnthalpy> > > >::correct() at ??:? #4 ? at ??:? #5 __libc_start_main in "/lib/x86_64-linux-gnu/libc.so.6" #6 ? at ??:?
24 March 2021 0 0 View
I have dataset which shows the length of power lines. I need to classify the lines based on the line length. Is there a rule to classify the High voltage (HV) and low voltage (LV) lines based on...
03 March 2021 4,116 4 View
What's the best way to measure growth rates in House sparrow chicks from day 2 to day 10? Since, the growth curve from day 2 to 10 won't be like the "Logistic curve" it might not follow logistic...
03 March 2021 1,401 3 View
I looking for ferro calcium production process
03 March 2021 1,755 4 View
Hello, good day! I am trying to simulate similar bimorph piezoelectric harvester with below commands. However, the output power doesn't change with resistor value. Please help to find the reason. ET,10,CIRCU94,0 !SET UP RESISTOR R,1,100000 !RESISTANCE VALUE TYPE,10 !SET ELEMENT TYPE E,1,2 !CREATE RESISTOR BETWEEN NODES 1 AND 2 Thanks in advance Regards,
02 March 2021 0 0 View