Is It possible to electroplate Cu on tungsten? (tungsten as Seed layer)
When I conducted the degassing experiment using decompression under anaerobic condition(and I used ferrous based chelating agent), the oxidized ferric were observerd. So, could you tell me the...
03 March 2021 4,892 5 View
Hi, everyone. I'm a starter to write a paper by Latex. But I have some difficulty using it. I'm writing the paper with 2 columns. And, there is one figure that occupies the 2 both-sides. I want to...
26 February 2021 3,738 3 View
Hello, I am a master's student studying in Yonsei Univeristy, Korea. I am trying to estimate the state of satellite, using Neural Network. Below is a simple flow of my study. 1. Train (t0 ~ t1)...
23 February 2021 6,383 3 View
23 February 2021 9,253 1 View
Hello, I've got a plan to isolate mouse splenic Treg (WT and KO of target gene) and inject these CD45.2 Treg into tumor-bearing CD45.1 mice. My question is how many days do I need to wait to see...
11 February 2021 8,238 1 View
Hello, I studied how much bound my test antibodies to the target antigen using FITC labeling to test antibodies. I tested 3 types of antibodies, the elisa binding affinity and cytotoxicity...
07 February 2021 8,335 2 View
I am trying to run a cell viability assay with LN229, but these cells are cultured in DMEM which contain phenol red. Is the MTS assay sensitive to the additional of phenol red in the media? If so,...
03 February 2021 9,478 2 View
I am currently setting up our lab's behavioral space to run the open field test in rats, and I am trying to figure out how to set up lighting to evenly illuminate the open field chamber (a 90 cm x...
26 January 2021 1,399 3 View
Hi guys, I'm looking for a water-soluble dye which is not surface inactive in order to observe (water in oil) emulsions; I don't prefer to use oil-soluble dyes. I've used rhodamin123,...
21 January 2021 8,496 2 View
I artifically elevated the air temperature in the heated plot by 3-celsius degree compared to that in the control for 7 days. I want to figure out the effect of the temperature manipulation on...
21 January 2021 1,185 8 View
I need the complete setup information.
21 January 2021 6,455 4 View
Anodizing of SS304 creates a thick oxide layer on that. Is this layer non-electrical conductive? What thickness should be obtained in order to make the surface non-electrical conductive?
01 January 2021 3,359 4 View
I'm setting up an electrophysiology rig examining LTP in the CA1 region of the hippocampus. What is an appropriate tip diameter size for a stimulating electrode to generate fEPSP? Also, I'm...
01 December 2020 5,139 2 View
For my B.Tech final year project I want to test multilayer coated carbide insert and test it for tool life and wear properties. I am looking for CVD and PVD facilities that can coat tungsten...
08 November 2020 8,091 4 View
05 October 2020 2,899 3 View
The use of nano tungsten for staining polymer nano particles is what I have been doing but in certain publications they use Uranyl acetate. What is the reason for the difference.
19 September 2020 4,159 4 View
Hi everyone I want to make a HgSO4 1 Molar solution for deposition (electroplating) in my electrode, but HgSO4 is not soluble in water! What can I do !? Because My other solutions are all in water.
14 September 2020 3,461 3 View
In the metallurgical lab we are used to working with destructive testing methods to characterize the properties of the different elements/parts, but sometimes it comes to analyze functional parts...
26 August 2020 5,890 3 View
Dear All, In XRD data, How the addition of organic additive influenced the average size of the crystallites of metal electrodeposition (Electroplating)? Regards, Hani
26 August 2020 1,870 7 View
Hello everybody, I would like to perform a CFD simulation to visualize the fluid flow in an electroplating tank. This big tank (400 L) is mixed with several eductor nozzles. I would like to know...
13 August 2020 7,426 3 View