Is It possible to electroplate Cu on tungsten? (tungsten as Seed layer)
Currently, when I run SDS-PAGE, I don't see any bands at all, even though I used the same material just a day ago and it worked fine.... In our lab, we dilute the 10X running buffer to 1X and...
06 August 2024 5,373 2 View
I'm working on the atmospheric water harvesting, and i synthesized MOF by adding some materials into precursor and changing the conditions. (i followed Hydrothermal method) Actually, if MOF is...
24 July 2024 1,515 0 View
UK's Well-online Science Press sent an invitation to be a co-author and offers a payment of $30 per review.
22 July 2024 1,695 8 View
I want to express STK4, and I've searched the paper for reference. When I check the protein kinase domain sequence for that kinase on Uniprot, it's 30-281, but the paper expresses the protein...
20 July 2024 4,951 1 View
I am planning to use CD4 Cre mice crossed with Loxp mice. However, the laboratory from which I am trying to get the loxp sperm says they have "the product of the EMMA ko crossed with the FLPe to...
16 July 2024 7,475 1 View
I am preparing cancer cell conditioned media to study the effects of substances secreted by cancer cells on other cells. In some papers, conditioned media is prepared using FBS-containing media...
11 July 2024 7,063 1 View
Hello, I'm generating stable cell lines by transfecting plasmid DNA with lipofectamine 3000. The cells went through antibiotics selection for 3 weeks (polyclonal selection) and when I analyzed...
11 July 2024 4,812 5 View
Hello, I am an Etch Engineer. I am performing etching with high T_ox/Nit selectivity using remote plasma. Etching plasma is formed using only NH3/NF3/H2. 1. I wonder if it would be advantageous...
11 July 2024 8,115 2 View
Hello, So I have mouse brain tissue MS data from one of my predecessors and I have human serum data from the hospital that I collaborate with. We are trying to find markers for the diagnosis of...
11 July 2024 8,484 0 View
Hi, I'm a graduate student, college of nursing, chungnam national university in Daejeon. The topic of my thesis is "Quality Assessment of Tools for Evaluating Acute Postoperative Pain." I have...
10 July 2024 3,048 1 View
We are fabricating a tandem structure where a ~50 nm thick WO3 film is deposited between two metal films using DC sputtering. We use a mixture of Ar and O2 gases at different flow rates while...
01 July 2024 2,686 2 View
I have to join tungsten wire to metallic plate with that adhesive and entire assembly has to be heated upto 600C in ultra high vacuum. I know about zirconia paste but it is not readily available...
18 June 2024 3,092 3 View
Dear fellow researchers, We are currently operating a Philips XL30 Scanning Electron Microscope (SEM) equipped with a tungsten filament and have encountered a significant issue. Recently, our...
28 May 2024 232 2 View
28 May 2024 9,415 2 View
I've tried to prepare a thin film of tungsten oxide nanoparticles on glass plate with the help of following methods- 1. Nanoparticles were dispersed in Poly-ethylene glycol (PEG) and the...
16 May 2024 9,007 1 View
Hello Members, I am facing an issue with chip formation in a 3D turning process simulation, and I would greatly appreciate any insights or suggestions on how to address this problem. I have...
02 April 2024 2,110 0 View
My sample has Tin electroplated on Copper. I want to selectively etch the Tin.
10 March 2024 6,990 3 View
Deionized or distilled water—which is a better choice for electroplating?
01 March 2024 3,813 3 View
Hi, we establish new radiochemical laboratory: now I deal with task to find an adequate instruments for alpha radiation sample preparation? Do somebody have some recent experience? Is the cell in...
29 February 2024 5,846 3 View
Hello everyone, I am actually performing a corrosion rate analysis for a sample of aluminium that is electroplated with nickel. I am using Linear Polarisation using the Palmsens EmStat 4s...
26 February 2024 3,319 2 View