Get answers to your research questions and share your expertise.
Bujji Reddy Kanchi
how to select a GC Column for residual solvents, for instance USP G1 Column will be good for what type of solvents ?
Dear Bujji,
The attached file contains all available GC columns and solvents that are successfully determined by them.
Please note, that the GC column in USP might be different from the original column produced by the company.
G1 columns are composed of dimethyl polysiloxane.
Hoping this will be helpful,
rafik
Please explain volumetric KF titration and Coulometric titration for determination of water.
04 May 2016 3,173 3 View
which guidelines are supposed to be learned for Regulatory affairs ?
04 May 2016 3,488 1 View
how to develop a HPLC method ? selection of mobile phase and column, any reference guide ?
03 April 2016 957 4 View
A crude extract of fungal culture using EtOH was subjected to column and TLC and partially purified compound was obtained. UV vis spectrum of the compound/s has max absorbance at 218nm. The...
11 August 2024 9,801 2 View
Can anyone explain this method? Especially the last statement where it says only at 1.5 to 2.5mins was the MS/MS connected to the UPLC. How is that possible, is it a feature in this specific...
11 August 2024 8,141 3 View
Hello experts, Does anyone know any free software about retention index prediction ?
08 August 2024 7,403 2 View
I've been performing RNA extraction on cotton petiole tissue for a few months now using the method described in the following paper, a derivative of the typical hot borate method...
08 August 2024 9,882 2 View
I'm working on selecting antibodies against a recombinant protein that has a His-tag. My idea is to first bind the recombinant protein to a HisTRAP column and then use this column for an affinity...
07 August 2024 505 3 View
I need to do some experiment with it in liquid form.
07 August 2024 613 3 View
Dear QE-users, In the method where full MS positive mode and PRM mode are used, we always get an incorrect auxiliary gas reading (41 instead of 25). This only happens in this method; other...
06 August 2024 4,953 0 View
I am trying to recover liquid CO2 from a mixture of 0.6 CO2, 0.3 N2, and 0.1 O2. My aim is to recover about 99% liquid CO2 at the bottom of the column and make sure the amount of gaseous CO2...
06 August 2024 4,611 0 View
Hello, Can anyone provide me with the absorption coefficient of methane gas at 7.7 um? Any reference?
06 August 2024 980 5 View
There are anaerobic gas pak jars and environment providers in the laboratory that provide anaerobic environmental conditions for the growth of anaerobic bacteria. However, there is no anaerobic...
05 August 2024 4,945 3 View