16 June 2021 12 10K Report

Hi all,

I'm doing an optimization for ZnCl2 in acetonitrile solvent using Gaussian DFT method. The command line is below:

#p M062x/6-31+G* opt SCF=QC freq scrf=(smd,solvent=Aceton

itrile) integral=ultrafine

The calculation always ends with 2 negative frequency with many tries. I also tried to use 6-31++G** basis set and opt=tight, but the negative frequencies kept showing up. The negative frequencies are up-down and back-forth bending models.

This is the convergence result when using 6-31++G** basis set and opt=tight command:

Item Value Threshold Converged?

Maximum Force 0.000000 0.000015 YES

RMS Displacement 0.000000 0.000010 YES

Maximum Displacement 0.000002 0.000060 YES

RMS Displacement 0.000001 0.000040 YES

The convergence parameters turned to be reliable, but the frequency data tells me there must be something wrong in the result.

Please let me know if I did something wrong in the calculation that lead to this result. Your suggestions and help are much appreciated!

More Wenda Wu's questions See All
Similar questions and discussions