I want to check the electrical property of La2CuO4 Nanoparticles. It is p-type semiconductor.
I trapped the La2CuO4 NPs at the electrodes by dielectrophoresis method, as seen in picture.
When I checked the electrical property, the sample has no current, I expected this is because no ohmic contact between my sample and electrodes.
I tried many electrodes materials such as Al, Au, Pt because it has higher work function.
And I also annealed the device first before measurement, but it is still same.
Anyone have suggestions for my problem?
Thank in advance.