I am trying to compute the Lithium-ion diffusion coefficient (DLi) based on the equation attached[1].
So how do I get the A; electrode surface? and also how to calculate the dE/dx part of the equation?
The dE/dx corresponds to a single point on the plateau, but which concentration should I choose?
You should measure BET your active material. Based on loading level of your electrode, you can calculate the A. What experimental method did you use for calculating DLi? CVs or GITT, ..etc?
Hi Danthien!
I performed experiments using CVs ang galvanostatic charge-discharge.
[Q : which concentration should I choose?]
DLi(x) : is a function of the concentration x.
Hi, I would like to ask some insight about how to choose a reliable set of competing compounds for chemical potential diagram? For example an Li-Ti-O phase diagram has 19 stable compunds, would...
11 December 2016 2,684 0 View
Assuming NaCl Structure
31 December 2015 5,685 3 View
Surface area, particle size? What other possible factors reduces/increases Electrode Polarization? And how does Electrode Polarization affect affect rate-capability and battery performance?
11 December 2015 1,708 7 View
I’m trying to reproduce the acousto-optic coupling simulation in the paper Frequency–angular resolving LiDAR using chip-scale acousto-optic beam steering. LNOI(lithium niobate on insulator) is...
13 August 2024 9,795 0 View
I would like to learn more about SPSS and Its application especially in regards to data analysis. Please suggest me how I can learn more about it. Thank you so much.
11 August 2024 9,101 4 View
I have reverse sequences (AB1 format), can I base on reverse DNA sequences to perform nucleotide alignment, convert nucleotides to amino acids and deposit the sequence in GenBank database?
11 August 2024 5,138 1 View
Hello, Why do i see this baseline drift when i compare my blank (black) to the sample (blue)? Any suggestions as to why this happened? Thank you!
11 August 2024 3,770 4 View
I tried four trials of the same Copper Phosphides sample in Alkaline medium ( 0.5M KOH) with Hg/HgO reference electrode and Pt as counter electrode. I used 0.001 V/s scan rate for first three...
10 August 2024 3,629 1 View
Willett, Shenoy et al. (2021) have developed a brain computer interface (BCI) that used neural signal collected from the hand area of the motor cortex (area M1) of a paralyzed patient. The...
10 August 2024 7,180 0 View
I'm currently exploring the application of Python in textile engineering, specifically in areas like data analysis, process automation, and the development of smart textiles. I'm interested in...
10 August 2024 7,429 2 View
How can I use the cif data obtained from rietveld refinement extracted via gsas2, for microstructural analysis using ETEX software?
09 August 2024 7,718 0 View
Let's say we have a standard, regular hexagonal honeycomb with a 3-arm primitive unit cell (something like the figure attached; the figure is only representative and not drawn to scale). The...
07 August 2024 1,937 1 View
A fungal strain was treated with nanoparticles. We want to do an environmental SEM analysis. So could anyone share your views on preparing the sample? Thank you.
07 August 2024 5,307 1 View