I am trying to analyze DC arc fault current in time domain. How can we derive the related equations which then I need for secondary computations such as fourier transform.
I am thinking about measuring the input/output data for obtaining an auto regressive moving average model of the electric arc. dont know whether it will describe its behavior properly...
Good idea. I afraid the ARMA model cant be able to capture model nonlinearity. I will find out soon and let you know by sharing the results. Thanks aparna for your support