sybyl x protein - ligand complex
If you mean docking results, you will find the protein and ligand in the file of docking results. open them by PyMol and do what you need.
I hope that is clear.
Never use Sybyl. But I know how to separate the complex. First you need to know the residue number of receptor and ligand. Then use VMD, you can save the selected residue to a new PDB file.
beta lactamases...the numbers OXA-23, OXA-143, KPC-2, IMP-1 what these numbers are denoting?.
06 July 2017 6,843 2 View
I want to do MD simulation for metallo enzyme as well as protein-ligand complex in GROMACS. But when i use the pdb structure with zn ions it showing error. Help me to sort out this problem. Which...
10 November 2016 4,644 4 View
suggest tools to repair missing residues in PDB coordinate file
05 June 2016 2,849 2 View
In grompp in ion.trp filr creation there occur error. Fatal Error, Too much Warning (1), use option -maxwarn. could anybody tell me how to use this option, if i use this option its asking for...
02 March 2015 9,510 3 View
gromacs tutorial for simulation
02 March 2015 3,879 0 View
rectify my error Fatal error:Atom HB3 in residue SER 3 was not found in rtp entry SER with 8 atomswhile sorting atoms.
02 March 2015 2,299 10 View
gromacs forcefield error
02 March 2015 7,152 2 View
I'm referring to molecular docking sybyl version 2.0
09 October 2014 8,440 5 View
Hi! So i attempted to understand a novel protein behavior towards heat application by analyzing its secondary structure change. I subjected the protein to a thermal denaturation analysis using...
06 August 2024 1,989 3 View
Hi, I know that low molecular weight (MW) molecules generally tend to have higher mobility, while high molecular weight molecules tend to have lower mobility. However, in my experimental...
06 August 2024 1,495 2 View
kindly reply me. Thanking you in advance.
05 August 2024 7,727 4 View
why don't d-orbitals split themselves because of themselves without the presence of ligands? Electrons are indistinguishable. Why wouldn't it be more correct that protons from a ligand split the...
03 August 2024 3,589 3 View
I'm guessing it's because the ligand experiences too much electron repulsion or proton repulsion from the chromium to insert them close to the 3d-orbitals which are close to the metal nucleus. Is...
03 August 2024 1,370 1 View
Is it possible to conduct a molecular dynamics simulation to see the effects of a specific carbohydrate on the structure of lipids (e.g., micelle structure)? I am a beginner in this field and plan...
03 August 2024 3,371 3 View
I am using a windows system, what software I should use for hydration shell analysis with molecular dynamics?
02 August 2024 3,143 4 View
Molecular docking software/ websites?
02 August 2024 8,704 7 View
Dear All, I am trying to transfect a pCDNA3.1 vector containing my gene of interest. The purpose is to figure out the localization of the protein of interest. I have fused the protein with GFP on...
31 July 2024 9,892 4 View
Can we patent a process flow diagram developed using a process simulator but no actual cases is carried out? For example consider a process for certain product manufacture where a new process flow...
31 July 2024 781 1 View