For example, if K2O wt% is 0.29 then how much is K%. Is there any standard calculation system/excel template for all the elements. I need for Ti% from TiO2, Fe% from Fe2O3, Na% from Na2O, Ca% from CaO, Mg% from MgO, Si% from SiO2 etc.
Dear phani , normally analysts use FACTORS for "elemen to oxides conversations" and vice versa... Please find attached a table of conversion
Dear Zeeshan, Thanks for immediate response. Using these factors, what is the unit of element concentration estimated? Is it %?
Sur.. It will be in %age
Recent studies revealed that age of lower Coddapahs is Palaeoproterozoic. Howerver, in majority of previous publications, it is referred to as Mesoproterozoic. In some publications...
03 April 2019 3,468 1 View
Hello, We would like to increase the yield of our PCR product. We are running a series of PCR reactions that is targeting ~1.1kb sequence. We begin each reaction with ~400pg of template DNA...
02 March 2021 4,029 3 View
Favourable conditions of base pressure, rate of deposition. Also, by which characterisation technique to be used to verify the thickness of the deposited film.
28 February 2021 3,640 3 View
I have always been interested in geology and wondered about how unique structures of materials behave in different circumstances. I stumbled upon Olivine, the magnesium iron silicate, and heard...
28 February 2021 7,330 4 View
Dear all, I am trying to perform a MD simulation about the interaction between CO2 and a polymer. I create my model, solvate it and perform the NVT and NPT equilibration. Now I am not able to...
26 February 2021 10,014 3 View
Has anyone ever tried to deliver CO2 with a CGA 300 regulator? I know that a CGA 320 regulator is standard for CO2. The issue is that I currently do not have any free CGA 320 regulators. I also...
25 February 2021 3,292 3 View
I tried coating Fe3O4@ SiO2 by using APTES in 5% water-ethanol but it is not coated. Kindly suggest a solution for it. Thanks
24 February 2021 5,992 4 View
We have recently purchased a triaxial test instrument (MATEST) for testing different types of soil. After installing software, we are facing a issue of saturation where the samples does not...
23 February 2021 7,194 4 View
As a beginner in electrochemistry, I tried to obtain cyclic voltamograms of commercial anatase powder deposited on an ITO substrate or on Eteck. After several attempts, I noticed that my cyclic...
23 February 2021 3,175 3 View
I notice that upon washing and air-drying of my RGO/SPCE surface and characterizing again via DPV, the current response towards ferricyanide probe significantly decreases. My worry is that the...
22 February 2021 5,324 3 View
I want to measure the thickness of aluminum oxide and titanium oxide layers deposited on textured glass substates. The layer thicknesses are typically below 100nm.
21 February 2021 5,465 4 View