How to investigate the hollow cathode electron oscillation? Is the length of the output plume dependent on this oscillation? what is the effect of this oscillations on generated discharge?
You can read about hollow cathode effect in [1]. A recent publication on the subject is [2].
[1] A Piel, Plasma Physics, 2nd edition (Springer, Berlin, 2017).
[2] MP Georgin et al., 2018 Joint Propulsion Conference, Cincinnati, Ohio
Conference Paper Plasma Instabilities in the Plume of a Hollow Cathode
see
Role of additional gas ionization by oscillating electrons within the cathode fall region of a glow discharge with a hollow cathode
A. S. Metel', A. I. Nastyukha
https://booksc.xyz/book/12183377/3ed58e
I applied the bias voltage to Langmuir probe in DC discharge and provided the characteristic I-V inversion of references. (with proportion gradient ).
01 January 1970 2,373 1 View
i have problem in preparation of liver tissue with bad cell organelles and how i can adjust osmolarity
03 March 2021 8,890 1 View
Need to image mesoporous silica nanoparticles using the TEM. Also, need high resolution TEM images to see the mesoporous structure. Kindly suggest what kind of grids to use. Thanks, Shatadru
02 March 2021 1,787 2 View
I am using a Sutter electrode holder for my patch clamp experiments, but I'm having trouble keeping positive pressure inside my electrode due to a leak out of the back of the holder. I have added...
02 March 2021 5,829 1 View
I want to do RF sputtering of ITO on glass substrate using magnetron sputtering. what thickness do i need to make it good conductive layer to use it for PSC. Moreover, whats about thickness of...
01 March 2021 395 3 View
Hello everyone, I had run a mediation model in SmartPLS using questionnaires that were already validated among my statistical population. A professor who edited my paper -though she is not...
01 March 2021 3,052 3 View
I am conducting anodic electrodeposition of MnO2 onto a stainless steel substrate, using a platinum strip as a counter electrode. This is done galvanostatically, with the current held between 5...
27 February 2021 1,829 3 View
Hello, I have three hypothesis to test, all with the same IV. I am testing if the effect of the IV on the first DV is mediated by awe. I am then measuring whether the effect of the IV on a...
26 February 2021 8,399 5 View
During performing CV of a GCE or modified GCE, we rise the potential in the first half of the cycle and reduce it in reverse half. During the first half, what is the nature of charge on GCE or...
25 February 2021 7,994 3 View
I am trying to characterize an electrochromic system. The system uses ITO electrodes on glass, WO3 as the electrochromic film, and NiO as the ion storage layer. When I deposit NiO and WO3 and...
23 February 2021 9,592 2 View
I need to clean the hydrocarbon contamination on the carbon substrate of TEM grid. However, I heard that substrate could be broken by the powerful plasma. My substrate is pure carbon, with ~3nm,...
23 February 2021 3,262 5 View