Hi everyone! I'm trying to implement an extractive distillation process in Aspen Plus. The DSTWU model works completely fine. When I use the results of the DSTWU results to transform the model to a rate-based RadFrac model, the model does not work as well as expected (in numbers = the purity of the desired product after the first column decreases from 0.99 to 10^-4).

As a recap: In the first column, the solvent is added to the azeotropic mixture. The solvent and the desired product go to the bottom of the column. In the second column, the solvent is separated from the desired product (top of the column).

The problem is in the first column where the solvent is added to the azeotropic mixture. I tried several things: adjusting the convergence method, adjusting some parameters by executing some sensitivity analyses (for example: on the reflux ratio, the position of the feed stage), etcetera. However, nothing seems to work.

My question is: does anyone has any idea how to improve the performance of the first column? The convergence method is currently "strongly non-ideal liquid" since the convergence method "azeotropic" gives the following error: "RATESEP CALCULATIONS FAILED TO CONVERGE VARIABLES STAY ON BOUND"

Thank you in advance!