I want to use FIB milling technology for drug localization. Could any one suggest me to some articles regarding this topic.
Do you mean drug localization within biological tissues?
yes sir @ G.F. Goya
To identify a small drug molecule within cell or tissues is extremely difficult because lack of contrast. You sould label de drug with some heavy element, and deliver enough amounts to detect these elements by EDX.
Concentrating protein from 100 ml to 20 ml before chromatography
08 October 2019 1,076 4 View
I came to know, after UV excitation, the larger gold particles emit red light and smaller particles emit violet light. Is it right? Is it opposite to visible light?
24 March 2019 1,188 0 View
hi can any one let me know which graphene is suitable for device applications the single layer or multiple layer and why?
12 April 2016 999 4 View
I'm currently working on calculating the collision cross section (CCS) for various ions, and I'm facing challenges when dealing with sodiated and multiply charged ions. Most of the resources I’ve...
08 August 2024 8,329 0 View
I'm having problems with ion exchange chromatography. After applying my sample (a fluorescent protein), a preferential path inevitably forms. The matrix I use is DEAE-Sephacel. Could someone...
27 July 2024 6,605 0 View
Can diamond be grown using molecular beam epitaxy?
22 July 2024 9,755 2 View
The column is used in Ion Exchange Chromatography of Monoclonal antibodies and the method of analysis is based on pH gradint.
13 July 2024 7,462 1 View
Would an average spot welder suffice for welding tabs for pouch cell electrodes instead of an ultrasonic one? Why would an ultrasonic welder be better than a regular spot welder?
10 July 2024 8,763 0 View
We have observed many holes on the surface of TiO2. These holes have a diameter of approximately 1 µm and a depth of about 30 nm. The formation of these holes is mainly related to the...
20 June 2024 3,861 1 View
Hello, Everyone! I need a Python or Matlab code that calculates the cyclic and calendric aging of LFP batteries. There are numerous semi-empirical aging models for lithium-ion batteries, but I...
16 June 2024 1,861 2 View
I am currently using API4000 from SCIEX and I have a problem with some unknown contamination. I can see some white powder surrounding the orifice of the curtain plate and some unknown powdery...
10 June 2024 9,605 8 View
I measured the wastewater sulfate addition with Thermo Ficher Ion Chromatography (IC) (eluent NaOH of 25 mM w/w), as I used standard solutions of sulfate in the ranges of 50 ppm, 150 ppm, 300 ppm,...
27 May 2024 9,103 5 View
Hello, In the standard TMT SPS MS3 method, ion trap is used as detector for ms2 data acquisition. In my experiment, it would be much beneficial to use Orbitrap for ms2 data acquisition to obtain...
26 May 2024 628 0 View