Hello all,
I want some recommendations for spectrometers of UV to near IR (230 nm to 900 nm), with High resolution, have a good price, can distinguish between second and third harmonic, and are easy to use.
Thank you.
Avantes spectrometer is highly recomnded in terms of product price and benfits
https://www.avantes.com/products/spectrometers/starline/
you can perform easily spectral scanning.
If you are interested in photon counting and high resolution Andor is one posibility, but you should know your need for that.
Good luck,
Thank you so much Hani Barhum
Hi, I was wondering in hollow-core fibres should the effective index of the fundamental mode be higher or less than the core's refractive index (in this case, n = 1 because the core is filled...
17 January 2021 2,220 3 View
I am trying to measure the energy in (Joules) in a Surge Arrester MOV. I am simulating a Hybrid DC circuit breaker.
17 April 2020 259 3 View
I am simulating a Mechanical DC circuit breaker. I used a step to put on and off. I wanted to use a "compare to constant" block so that when the fault current goes over the threshold the ideal...
24 March 2020 1,709 3 View
Hi I am trying to simulate DC circuits; MCB, SSCB and HCB but i cannot find a model i can use. Does anyone know a journal or a simulink model i can use. Any help will be really appreciated. Thanks
17 March 2020 7,696 3 View
Most of the academic journals take so long just to review the research paper, and most of the times they reject the paper. I was wondering if any researcher can send his paper to two journals,...
18 July 2019 4,444 9 View
I need to study the surface of nylon-6 blank fibres with a thickness of nearly 40 micrometre, I work in optics lab with many optical components such as beam splitters, lenses, mirrors ... etc, can...
18 March 2019 236 3 View
How much spatial change can amino acids of protein's active site withstand before being unable to perform protein's function? We can, for example, compare X-ray or NMR structure of protein with...
16 November 2016 4,954 3 View
Could you please answer for what may be the result/product when curcumin react with aniline or any other amine compound, pls suggest some references if possible. Some of researches are found as...
07 May 2016 286 4 View
10 March 2016 3,709 3 View
Polyaniline-based composite on GCE used for trimethyl, dimethyl and methyl amines through CV. In the case of TMA and MA the peak height was increased with increasing concentration, whereas DMA...
09 January 2014 9,090 3 View
Is There Any Feasible Method To Test The Efficiency Of Fluorescent Compounds Other Than UV Spectrometers ? Suggestions Would Be Appreciated !
02 March 2021 5,785 3 View
I am doing my thesis on the nutrient deprivation on the macroalgae Rhizoclonium sp. I will be analysing the levels over a period of roughly 5 days by HPLC-UV and GC/MS. I will be using seawater as...
28 February 2021 6,477 1 View
I need to simulate the optical properties of a biomaterial, namely DNA, in COMSOL. Basically I need to simulate the IR absorption spectrum of a cylinder filled with a 'concentration' of DNA. I am...
21 February 2021 3,043 3 View
Could the "incoming solar radiation" values be negative? What is the difference between "global solar radiation" and "incoming solar radiation"? Which one might be measured negative values?
21 February 2021 7,726 9 View
Hello, i work with a spectrometer which only render the fluorescence emission spectrum. Until now i just found how to interpret an exitation- and emission spectrum together to generate deeper...
20 February 2021 1,291 3 View
Hello, I'm working on removal of methylene blue. 01. in the dark test very first reading is taken 15 minutes after adding adsorbent to the dye solution and that UV absorbance reading is very...
19 February 2021 472 5 View
Good day, I design the rail-wheel geometry and the harmonic frequency ranges between 20-10kHz with 500Hz solution intervals and the results makes sense. Most of the time on the related literatures...
19 February 2021 3,190 3 View
Currently, I am working on PLA-PEG copolymer micelle for the drug delivery system. I have seen several papers where some researcher talks to centrifuge the drug-loaded micelle to separate the...
13 February 2021 5,822 7 View
Currently I'm doing a literature review regarding the comparisons of different types of radiation such as uv, electron beam and gamma radiation. But I'm having a difficult time converting uv unit...
11 February 2021 7,642 3 View
I did spectrum scan to levothyroxine sodium which show highest absorption at wave length=230nm which the absorption =0.136 and it's absorption at 225nm =0.047 but when Injecting it on HPLC...
09 February 2021 1,631 3 View