i am trying to correct he self absorption of LIBS data, which one method is the best method with less errors?
like
curve growth method
Black body radiation reference line method
etc....
Internal reference for self absorption correction is the method for intensity correction in LIBS. Choose a line that is free from self absorption and correct the intensities of other lines with it.
Following paper may be helpful for self absorption correction in LIBS spectra.
http://iopscience.iop.org/article/10.1088/1555-6611/aac9e5/meta
Please see following paper
We are working on Gold Nano particles and their peak absorbance is 1.8 unit for 570 nm. we want to extend this analysis towards spectrum band width and kinetics, please suggest some suitable...
08 September 2019 8,437 4 View
i am working on CF-LIBS, the stark broadening parameters are necessary for the calculation of electron number density and also for the elemental concentration. please suggest some suitable website...
07 August 2019 2,378 1 View
Please give me some logical hints or suggest me some Research papers about Celebration Curve.
07 August 2019 9,738 1 View
Is There Any Feasible Method To Test The Efficiency Of Fluorescent Compounds Other Than UV Spectrometers ? Suggestions Would Be Appreciated !
02 March 2021 5,785 3 View
Dear Researchers I am trying to perform a PIL simulation using STM32F4 Discovery board and comunication serial USB TO TTL. During simulation I receive the following timeout error: An error...
01 March 2021 2,327 1 View
I try to check the uv-vis absorption of Indium nanoparticle. Now I am measuring in solution, can I measure it in the form of a film?
01 March 2021 930 3 View
I like to do project in laser measurement system. My objective is to eliminate or reduce the cosine error, abbe error in Laser measurement system. I have Rhenishaw XL80 system. Please tell the...
28 February 2021 4,890 3 View
I am currently doing research on the adsorption of heavy metal using magnetic reduce graphene oxide. I use AAS to determine the concentration of the heavy metal. I prepare the Pb solution with...
26 February 2021 9,580 4 View
I am trying to find how to know the density needed for a pva electrospinning in a 0.6mm neddle, the electrospinning will be from top to bottom and the problem I really have is the solution because...
25 February 2021 2,615 3 View
25 February 2021 1,987 3 View
I would like to make a correction in a co-author in your paper which is wrong. This name is also in other papers of Kenton Ko. Zey Ko is not a Co-author . The correct name is Zdenka...
24 February 2021 3,476 4 View
As it is highly probable that pellets will have a higher degree of air gaps and voids than thin films, is it possible to pole the samples with corona poling nevertheless? Or is there the...
24 February 2021 1,349 1 View
Hello, I have run into an issue that has sparkled a debate at work: is the LLOQ/ULOQ impacted by injection volume under the following circumstances: 1) Same dilution factor of all samples 2)...
23 February 2021 9,159 3 View