Why is CPE used instead of a glassy carbon electrode, which is more common in film deposition?
I feel GCE is best option for acidic supporting electrolytes
Maybe, it's because using CPE you don't have to worry about cleaning steps between measurements, you just do other electrode easily. A GCE is a tool that you need reutilize, then you need to clean very well between measurements (or applications).
I am trying to reduce H2O2 at GCE and other modified electrodes using cyclic voltammetry. But I am not getting well defined reduction peak. Can anybody tell what could be the reason?
09 October 2016 5,100 5 View
If it is acting as cathode then why?
07 August 2014 3,222 3 View
How can we determine Fe(II)/ Fe(III) in a porphyrin ring?
06 July 2012 3,437 2 View
I have several question regarding the MOR; hope anyone help me better understand. 1- in CV using (KOH+MEOH) what is the indication of absence of the redox peaks? shouldn't they exist as a sign...
28 February 2021 4,851 8 View
As a beginner in electrochemistry, I tried to obtain cyclic voltamograms of commercial anatase powder deposited on an ITO substrate or on Eteck. After several attempts, I noticed that my cyclic...
23 February 2021 3,175 3 View
I performed a Proton NMR of graphene powder prepared by electrochemical exfoliation technique. It shows some peaks. But I can't understand it.
21 February 2021 8,947 3 View
Can anyone recommend some any software/models available that can predict substance reactivities and the reaction yield under a specific set of reaction conditions process and proposing pathways to...
17 February 2021 2,383 3 View
I have several questions, What reference electrodes is commonly used for aqueous electrochemical systems? What reference electrodes is commonly used for electrochemical systems which used...
06 February 2021 6,389 5 View
While surface roughness is an obvious factor, this is not what is exactly asked. Rather, periodic variation of exchange current density (of an electrode) with solution chemistry (of electrolyte)...
30 January 2021 4,886 5 View
I am trying to measure resistance from I-V curve from a chemiresistor/ FET sensor with a keithly sourcemeter. The substrate is soaked/ wet with protein and phosphate buffer only. But the I-V line...
24 January 2021 8,009 3 View
For example: In an electrochemical cell utilising a platinum (Pt) anode, what is the difference and what kind of implications would be expected from using either Pt(100), Pt(110) or Pt(111)?
20 January 2021 309 5 View
For electrochemical sensors, the electroactive surface area (ESA) show higher value for the working material as compared to bare (reported in several papers). My bare electrode is FTO and working...
17 January 2021 7,220 3 View
First of all, thank you for your consideration about this question. I've been working on development of in-vitro diagnostic medical device as research engineer since 2013. Especially, my major is...
14 January 2021 3,885 4 View