Hi,
I am new Quantum Espresso user. Can anyone please help me with the input for calculating IR and Raman spectra under a certain electric field in Quantum Espresso?
Thanks
Shawkat
Hello
The correct procedure for obtaining IR and Raman in QE is:
1. Firstl perform an Self Consistent Field (scf) calculation with pw.x
2. Calculate the vibrational frequencies (normal modes/phonons) with ph.x
3. Using dynmat.x parse the phonon information from ph.x output
4. again using dynmat.x parse ph.x output section that contains the spectra data (frequencies and intensities).
Here is an example https://github.com/maxhutch/quantum-espresso/tree/master/PHonon/examples/example15
Konrad
Hi Konrad,
I know that.
I wanted to calculate IR and Raman under a certain electric field, I want to know the input for that.
I run pw.x , ph.x then dynmat.x...
now how can I plot Raman ...??
Dr Vipin Kumar You may find Raman and IR data in the standard output file.
e.g.
$ dynmat.x < input.dynmat > stdout_dynmat
$ awk 'NR==1,/mode/{next}/DYNMAT/,NR==0{next}{print}' stdout_dynmat > plotdata.dat
Dear @Minkyu Park
Can I calculate Raman Peak intensity using qe? Or it only gives peak positions???
Dear Shahran Ahmed Joy this calculation will give you the intensity of the Raman active modes along with its positions.
Dear Guilherme Da Silva Lopes Fabris,can you please share the procedures? Because according
to the procedures similar to example, the calculation gives peak positions only.
I'm currently exploring the application of Python in textile engineering, specifically in areas like data analysis, process automation, and the development of smart textiles. I'm interested in...
10 August 2024 7,429 2 View
How to use ERP System in Global University ?
27 July 2024 8,229 0 View
here's a concise guide for preparing your CSV dataset in Excel to identify flood-triggering factors using an ANN: Clean and Format:Address missing values (fill with mean/median or remove if...
21 June 2024 7,941 0 View
how do integrate ECG, PCG, and clinical data to apply early fusion multimodal?
10 June 2024 3,289 1 View
I have performed the Molecular Docking using ADFR suite, I have obtained the files in _out.pdbqt format for ligand docked poses, upon inspection, both visually and reading the pdbqt files of...
08 June 2024 8,130 2 View
Dear Respected Scholars, I am working on detection of microplastic in prawn. Although, all the other parameters assessed smoothly but I have encounterd a problem during isolation of microplastics...
05 June 2024 2,469 0 View
In basin delineation and hydrological modeling, selecting the exact value in Flow Accumulation to identify streams is a critical step. The Flow Accumulation tool calculates the accumulated flow as...
30 May 2024 6,107 1 View
Are multi-level models appropriate for binary outcome variables for DHS datasets? If yes, what is the process?
30 May 2024 2,035 2 View
For my project, I need to extract RNA from muscle tissue of EEL. I am trying but the yield is low and Purity not good. The 260:230 ratio is always below 1.50 and 260:280 ratio ranges 1.6-1.86 and...
15 May 2024 3,024 2 View
For the design of three phase inverter for three phase motor drive, which is better using low DC voltage (12 V or 24 V DC) for the inverter stage then step it up using three phase transformer, or...
08 May 2024 3,491 3 View
Hi, Recently I was running VASP to calculate the spontaneous polarization of my alloy structure. I followed the instructions in this PDF wrote by Dr. Nabin (Nabaraj) Pokhrel, below is my INCAR...
07 August 2024 486 5 View
Hello everyone, I'm encountering an issue with my electrochemical impedance spectroscopy (EIS) measurements and would appreciate some insights. Experimental Setup: Electrodes: Gold interdigitated...
05 August 2024 3,783 2 View
Hello, everyone. I have tried to determine carrier motilities of some materials, by Density Functional Theory, using Quantum ESPRESSO. There are a few methods to do it, like a package called...
04 August 2024 8,894 1 View
Following curve related to Co0.6Mn0.4Fe2O4 Magnetic nanoparticles with extra phase a-Fe2O3. I will appreciate to help me to interpretation this spectroscopy, especially the blue line.
31 July 2024 9,140 2 View
I'm using a InVia Renishaw Raman microscope system (785nm wavelength, 600l/mm grating density) to acquire Raman images on human brain samples, at 50um resolution. The samples are placed on MgF2...
30 July 2024 8,771 3 View
Hello everyone, I am new to this characterization but watching videos on youtube I have already plotted a Nyquist plot (Z' and -Z'') and already fitted models on my material using Zsim. But now I...
29 July 2024 1,376 0 View
Dear all, I have noticed, as the ZnO content increases, the Raman intensity at 100cm-1 also increases. However, there is a peak nearby at 130 cm-1, which I could not find in any paper related to...
28 July 2024 5,410 1 View
How to build a heterostructure in VESTA/VASP of two pristine materials having different space group and structure?
27 July 2024 739 2 View
Dear Siesta Users, I installed Siesta 5.0.1 and I want to use Grimme's D3 correction. According to the 5.0.1 manual, I could use a few parameters to include the D3 correction in the...
27 July 2024 5,748 0 View
While I am doing HER, I noticed that nyquist plots of Electrochemical Impedance Spectroscopy (EIS) is not complete. Will it affect for the Linear Sweep Voltametry (LSV) data? However, I can found...
26 July 2024 7,542 4 View