Length, inner diameter and film thickness : of the column ;
The temperature program for GC analysis ;
I fear that such complex (adduct) will decompose under the GC conditions. Lewis acid adducts are sentive to basic functions that may be present in the column film, and to water (hydrolysis.) What is the Lewis acid?
Thanks for your answer,
Lewis acid : Fe(III)
Ligand : DodecylBenzene sulfonate.
The sythesized complex is hydrophobic.
I suppose that this adduct or salt is not volatile enough for GC analysis.
thank you.
Zahira Chaieb, your complex is in a solid state
My DV - internal customer satisfaction
14 February 2023 3,842 1 View
i have seen many reports have used AFM images to find the thickness of graphene and graphene like structures. Is there any specific software or method to find the thickness of the Sheets.
14 January 2020 10,121 3 View
I used >600 degree C for the preparation of Carbon frameworks at 5 degree C /min heating rate for 1 hour using Ar gas as inert atmosphere. In literature it is confusing , many reports have...
06 January 2020 8,192 4 View
I have prepared Carbon frameworks at 700 and 800(degree C) temperatures. The Surface area obtained for 700 (degree C) is higher than 800 (degree C).
01 January 2020 6,659 5 View
Secondly: what should i consider as initial concentration (Co) ? is it the initial concentration of the solution in ppm or the initial absorbance of the solution? and what should be final...
27 December 2019 6,972 4 View
The file is attached for reference
08 June 2019 9,069 4 View
I need the procedure of extrction for various medical plants
27 March 2017 3,430 21 View
what the chief methods of measure the net energy
24 March 2017 382 11 View
How can reduced heat stress in poultry?
22 March 2017 863 32 View
Ineed procedure for extraction of olive
19 March 2017 5,941 11 View
A crude extract of fungal culture using EtOH was subjected to column and TLC and partially purified compound was obtained. UV vis spectrum of the compound/s has max absorbance at 218nm. The...
11 August 2024 9,801 2 View
Can anyone explain this method? Especially the last statement where it says only at 1.5 to 2.5mins was the MS/MS connected to the UPLC. How is that possible, is it a feature in this specific...
11 August 2024 8,141 3 View
Hello experts, Does anyone know any free software about retention index prediction ?
08 August 2024 7,403 2 View
I'm currently working on calculating the collision cross section (CCS) for various ions, and I'm facing challenges when dealing with sodiated and multiply charged ions. Most of the resources I’ve...
08 August 2024 8,329 0 View
I'm working on selecting antibodies against a recombinant protein that has a His-tag. My idea is to first bind the recombinant protein to a HisTRAP column and then use this column for an affinity...
07 August 2024 505 3 View
For example, I perform passivation process before electropolymerization of Py for adhesion to titanium surface. Is a similar or different procedure required for ITO? If necessary, I would be glad...
06 August 2024 3,176 0 View
Dear QE-users, In the method where full MS positive mode and PRM mode are used, we always get an incorrect auxiliary gas reading (41 instead of 25). This only happens in this method; other...
06 August 2024 4,953 0 View
Hello, Can anyone provide me with the absorption coefficient of methane gas at 7.7 um? Any reference?
06 August 2024 980 5 View
There are anaerobic gas pak jars and environment providers in the laboratory that provide anaerobic environmental conditions for the growth of anaerobic bacteria. However, there is no anaerobic...
05 August 2024 4,945 3 View
Why is TLC not a form of partition chromatography and paper chromatography not a form of absorption chromatography?
03 August 2024 7,035 3 View