I have Reflectance data how can I convert it to transmittance?
Thans All in advance
Dear Dr. Endris Taju Seid,
the band gap value can estemated from the incident photon energy and absorption coefficient, which calculate from absorbance and film thickness.
Best regards
I agree with Khalid Haneen
As a first approach :
R = reflectance
T = Transmittance
They allow to determine absorbance A = 1 - R - T
Then, as a function of energy, bandgap will be the energy where A takes off from zero.
what problem suitable to conducct meta analysis? what conditions should meet to conduct meta analysis?
15 March 2022 5,442 3 View
Good day, We are running a project where we are profiling oligosaccharides and monosaccharides from wheat flour samples. Our aim is to extract oligosaccharides directly from wheat flour for...
08 January 2022 4,658 4 View
I need any who can help me to analyze the land use/cover change using the intensity analysis framework Thank you
19 August 2021 8,740 9 View
I am very interested in this paper.
30 November 2020 4,781 6 View
The interested one.
30 November 2020 8,017 1 View
I am also interested inthis area.
23 November 2020 3,432 7 View
I am also interested to do this.
23 November 2020 7,504 4 View
I am working on research to do on the security of WSN.
23 November 2020 6,831 0 View
I have a research interest on the premeditation of heavy metal's, PAH ... with the composite nano particles of magnetite and activated carbon, if some one who have an experience how to make nano...
24 June 2020 7,510 0 View
I have already calculate AA,AG and GG genotype but Igot difficulty how to enter A allele and G allele in to SPSS and analyze to get P value,OR and CI
01 June 2020 7,534 3 View
A crude extract of fungal culture using EtOH was subjected to column and TLC and partially purified compound was obtained. UV vis spectrum of the compound/s has max absorbance at 218nm. The...
11 August 2024 9,801 2 View
Hello, Why do i see this baseline drift when i compare my blank (black) to the sample (blue)? Any suggestions as to why this happened? Thank you!
11 August 2024 3,770 4 View
Hello everyone, I'm encountering an issue with my electrochemical impedance spectroscopy (EIS) measurements and would appreciate some insights. Experimental Setup: Electrodes: Gold interdigitated...
05 August 2024 3,783 2 View
I'm researching light sources and their UV emissions. I'm curious if a 50W, 7500K conventional LED lamp emits any UV light. I found that a 200W tungsten lamp can emit up to 1.5 mW/cm² at 350 nm....
31 July 2024 3,843 7 View
Following curve related to Co0.6Mn0.4Fe2O4 Magnetic nanoparticles with extra phase a-Fe2O3. I will appreciate to help me to interpretation this spectroscopy, especially the blue line.
31 July 2024 9,140 2 View
Dear all! Oxygen vacancies do raise negatively the Fermi level by increasing the negative charge in the semiconductor crystal structure. In the case of n-type semiconductors, I wonder if this...
30 July 2024 8,339 2 View
Hello everyone, I am new to this characterization but watching videos on youtube I have already plotted a Nyquist plot (Z' and -Z'') and already fitted models on my material using Zsim. But now I...
29 July 2024 1,376 0 View
How can we calculate the percentage of configuration interaction (CI) in the UV output data of the Gaussian program? for example: Excited State 17: Singlet-A 5.1359 eV 241.41 nm...
28 July 2024 9,165 2 View
While I am doing HER, I noticed that nyquist plots of Electrochemical Impedance Spectroscopy (EIS) is not complete. Will it affect for the Linear Sweep Voltametry (LSV) data? However, I can found...
26 July 2024 7,542 4 View
Hey All! I am wondering what might be wrong with my band structure. I did the calculations using VASP and plotted the results using Origin. Although I have tried changing various input...
25 July 2024 2,920 11 View