I have the following information:
1. Current density: pA/cm2
2. Emission current: Mu A
3. Exposure Time
4. HT
5. Dark current
did you solve this topic?
I can measure the current for area pA/um2
Hi Gustavo,
Yes, we had calculated. We took help of some references like:
On the dose-rate threshold of beam damage in TEM
doi: 10.1016/j.ultramic.2011.11.016
and we published our work:
Evolution of thiol-capped gold nanoclusters into larger gold nanoparticles under electron beam irradiation
10.1016/j.micron.2017.01.002
best wishes!!
Thanks!!
We are about to publish same work relationship with this topic! The ref was very usefull!
Regards
It is difficult to weigh the pellet if I start with the low scale GO.
09 October 2015 532 7 View
I have virus (viral hemorrhagic septicemia virus) in suspension and the experiment will not involve cells. What level of TCID50 is preferred?
11 August 2024 3,115 1 View
I would like to learn more about SPSS and Its application especially in regards to data analysis. Please suggest me how I can learn more about it. Thank you so much.
11 August 2024 9,101 4 View
I have reverse sequences (AB1 format), can I base on reverse DNA sequences to perform nucleotide alignment, convert nucleotides to amino acids and deposit the sequence in GenBank database?
11 August 2024 5,138 1 View
Hello, Why do i see this baseline drift when i compare my blank (black) to the sample (blue)? Any suggestions as to why this happened? Thank you!
11 August 2024 3,770 4 View
Willett, Shenoy et al. (2021) have developed a brain computer interface (BCI) that used neural signal collected from the hand area of the motor cortex (area M1) of a paralyzed patient. The...
10 August 2024 7,180 0 View
I'm currently exploring the application of Python in textile engineering, specifically in areas like data analysis, process automation, and the development of smart textiles. I'm interested in...
10 August 2024 7,429 2 View
I am using Rhodamine6G as gain medium and silver nanoparticles as scatterers on a microscope slide and laser input 532 nm comes from above.
09 August 2024 9,894 2 View
How can I use the cif data obtained from rietveld refinement extracted via gsas2, for microstructural analysis using ETEX software?
09 August 2024 7,718 0 View
If we map as a continuous motion an ionising electron (beginning its journey at n=1) in an H atom, a specific hyperbolic spiral appears (see animation). When we solve this spiral formula, we find...
07 August 2024 5,343 2 View
Let's say we have a standard, regular hexagonal honeycomb with a 3-arm primitive unit cell (something like the figure attached; the figure is only representative and not drawn to scale). The...
07 August 2024 1,937 1 View