Hi to all
I am writing you in order to get more information about the procedure 3.2.1 on Arsenic determination in glass containers for pharmaceutical use. In the monograph, at the paragraph ”Reference solutions” it is reported:
“Prepare the reference solutions using arsenic standard solution (1 ppm As) R. Add 10 ml of hydrochloric acid R and 5 ml of 200 g/l solution of potassium iodide R. Heat on a water-bath at 80 °C for 20 min, allow cool and dilute to 100.0 ml with water R. The concentration range of the reference solutions is tipically 0.005 – 0.015 ppm of As.”
I am wandering how to execute the test. Should I have to react the 1ppm As standard and then dilute it to obtain the required reference solutions, or should I have to react 3 differently concentrated solutions in order to obtain the 3 reference standard solutions? thank you all for you concern.