I want to calculate the shielding effectiveness by using electrical conductivity, but don't know the formulae.
Please read the following file: http://ntrs.nasa.gov/archive/nasa/casi.ntrs.nasa.gov/19970036055_1997067804.pdf On page 24 you will find the general formula and the whole report contains much further info
@Gyorgy Banhegyi :- once again thanks for help sir
Calculate percolation threshold, then you got shielding effectivenss.
Article Modeling the electrical resistivity of deformation processed...
I am looking for exact copy number of pET28a plasmid. A citation would be great. Literature search only shows that it is low copy vector, but I haven't found any papers that mention the exact copy...
26 February 2024 2,359 1 View
I am working with a cyclic peptide and I would like to generate the stereo-isomers of my peptide. The stereo-centers are present in the ring. Is there a way I can do it, other than manually...
31 August 2023 7,196 0 View
Hi researchers, Can anyone help me to find out how we could equilibrate a system(step by step) by applying restraints to a desired set of heavy atoms using NAMD ? Thank you, Krithika.
16 November 2022 4,776 0 View
I was performing the equilibration and minimization of ATP in namd and vmd. This is the error message. FATAL ERROR: UNKNOWN PARAMETER IN CHARMM PARAMETER FILE top_all27_na.rtf LINE=** \\\\...
16 January 2022 7,634 21 View
My .pdb file is of a solvated ATP. I was trying to change the (res)name in the .pdb TIP3W to TIP using atomselect in tcl. But something is not working. I am confused how to select "TIP3W". I...
22 December 2021 968 4 View
How can I create a water box around our system with desired dimensions with desired number of solvent molecules around it (say a 50A x 50A x 50A cubic box containing 1000 water moleclues.) using...
26 July 2021 2,794 4 View
I am looking for an old gromacs version (v 4.6). I would be highly obliged if someone shares the tar files of the version. Thank you.
30 June 2021 8,534 3 View
While using pdb2gmx for ATP molecule, I encountered an error which shows, "Residue 'ATP' not found in residue topology database". So, I was trying to find force fields that natively supports ATP...
19 April 2021 8,664 5 View
Are there any past studies undertaken in India on this aspect? Up to what EC we can use saline water in drip irrigation?
23 August 2017 9,861 3 View
pure iron powder by electrolysis
03 January 2016 6,332 1 View
I know that films and other low-thickness laminated products are produced using biaxial orientation, but is there something similar for sheets with a thickness of around 6 mm? Or are they...
21 July 2024 1,559 1 View
We're studying the stability and fusion behavior of multiple PVC compounds in a Brabender. After a few trials, we set the temperature at 195 °C and the rotor speed at 70 rpm. Samples differ in...
12 July 2024 2,768 1 View
I am creating a single element model in Abaqus of a composite material. My goal is to match the stress-strain curve of the material which was obtained experimentally. I am using VUMAT for Fabric...
07 July 2024 10,036 5 View
In solid ceramic electrolyte what is the Physical significant of area under the curve in dielectric loss tangent studies ??
23 June 2024 4,354 1 View
I want to know the exact mechanism behind the motion of ions inside the polymer electrolytes.
13 June 2024 3,489 0 View
I searched everywhere and I can't find a single definitive source, the only paper that I found was this one:...
12 June 2024 3,126 3 View
I am currently working on my bachelor thesis in the field of back injection molding of textiles made of polyester fibers. We have achieved quite good results with thermal treatments to restore the...
01 June 2024 2,457 3 View
I have prepared some polymeric microspheres from chitosan and PCL. However while performing in vitro degradation study, I found difficulties in both above mentioned methods. Here I am mentioning...
20 May 2024 6,114 4 View
How can I find the Elastic properties of matrix material reinforced with nanofillers, is there any relation or formula to find it?
20 May 2024 5,653 1 View
What is the mechanism behind increase in the peak intensity with filler loading in polymer nanocomposite. In my work, the (014) peak corresponding to the filler increased proportionately with...
08 May 2024 7,972 3 View