While trying to run MD simulation for 50ns, i got some errors read as

"WRITING EXTENDED SYSTEM TO RESTART FILE AT STEP 500000

WRITING COORDINATES TO DCD FILE output.dcd AT STEP 500000

WRITING COORDINATES TO RESTART FILE AT STEP 500000

FINISHED WRITING RESTART COORDINATES

WRITING VELOCITIES TO RESTART FILE AT STEP 500000

FINISHED WRITING RESTART VELOCITIES

REINITIALIZING VELOCITIES AT STEP 500000 TO 310 KELVIN.

TCL: Running for 25000000 steps

ETITLE: TS BOND ANGLE DIHED IMPRP ELECT VDW BOUNDARY MISC KINETIC TOTAL TEMP POTENTIAL TOTAL3 TEMPAVG PRESSURE GPRESSURE VOLUME PRESSAVG GPRESSAVG

ENERGY: 500000 1758.0188 1801.9004 2376.2868 32.0673 -57791.6942 4645.6399 0.0000 0.0000 12929.5296 -34248.2515 314.2067 -47177.7811 -34247.2801 314.2067 -547.9328 -2890.9435 156892.4304 -547.9328 -2890.9435

ERROR: Atom 4439 velocity is 4671.87 1153.77 2833.69 (limit is 5000, atom 327 of 328 on patch 18 pe 1)

ERROR: Atoms moving too fast; simulation has become unstable (1 atoms on patch 18 pe 1).

FATAL ERROR: Exiting prematurely; see error messages above.

FATAL ERROR: Exiting prematurely; see error messages above."

The error happens just after minimzation is complete and the running for 25000000 steps just started. Any recommendation to solve this problem?

More Suraj Pukhrambam's questions See All
Similar questions and discussions