more details about this report is:
Evans, L T., and Duncan, J. M (1982). "Simplified analysis of laterally loaded
piles." Report No. UCB/GT/82-04. Department if Civil Engineering University
of California at Berkeley, 224 p.
The NISEE library at UC Berkeley has these reports:
https://nisee.berkeley.edu/elibrary/Text/2008010916
You can find it in google scholar.
Mr.Elmira,
You can collect this report from the author..since authors name and affiliation is known to you..so you send request mail to them..definitely they will send the copy to you..ok all the best..
thank you Mr Karthigeyan . S
I found the report and I added it here.
Excessive rotation of nodes in node set ErrNodeExcessRotation-Step1
17 August 2021 0 0 View
20 June 2021 0 0 View
What this unit identifies for the ion exchange capacity ca. 0.92 meq. g-1. I am a newcomer in the membrane area. I just started. I highly appreciate your help
08 May 2021 0 0 View
--> FOAM FATAL ERROR: Maximum number of iterations exceeded From function Foam::scalar Foam::species::thermo::T(Foam::scalar, Foam::scalar, Foam::scalar, Foam::scalar (Foam::species::thermo::*)(Foam::scalar, Foam::scalar) const, Foam::scalar (Foam::species::thermo::*)(Foam::scalar, Foam::scalar) const, Foam::scalar (Foam::species::thermo::*)(Foam::scalar) const) const [with Thermo = Foam::hConstThermo >; Type = Foam::sensibleEnthalpy; Foam::scalar = double; Foam::species::thermo = Foam::species::thermo >, Foam::sensibleEnthalpy>] in file /home/ubuntu/OpenFOAM/OpenFOAM-4.1/src/thermophysicalModels/specie/lnInclude/thermoI.H at line 66. FOAM aborting #0 Foam::error::printStack(Foam::Ostream&) at ??:? #1 Foam::error::abort() at ??:? #2 Foam::heRhoThermo >, Foam::sensibleEnthalpy> > > >::calculate() at ??:? #3 Foam::heRhoThermo >, Foam::sensibleEnthalpy> > > >::correct() at ??:? #4 ? at ??:? #5 __libc_start_main in "/lib/x86_64-linux-gnu/libc.so.6" #6 ? at ??:?
24 March 2021 0 0 View
I have dataset which shows the length of power lines. I need to classify the lines based on the line length. Is there a rule to classify the High voltage (HV) and low voltage (LV) lines based on...
03 March 2021 4,116 4 View
I looking for ferro calcium production process
03 March 2021 1,755 4 View
Hello, good day! I am trying to simulate similar bimorph piezoelectric harvester with below commands. However, the output power doesn't change with resistor value. Please help to find the reason. ET,10,CIRCU94,0 !SET UP RESISTOR R,1,100000 !RESISTANCE VALUE TYPE,10 !SET ELEMENT TYPE E,1,2 !CREATE RESISTOR BETWEEN NODES 1 AND 2 Thanks in advance Regards,
02 March 2021 0 0 View
Which is suitable for use with Python? MySQL or SQL Server? What is your suggestion?
01 March 2021 3,422 3 View